8 Jul electrical specifications of ASTM F [4]. Ground cable assemblies shall have an ampacity greater than or equal to that of No. 2 AWG copper. ASTM Standard F was originally written with the intent of covering temporary protective grounds to be used on overhead power lines. The standard was bas. Abstract– During implementation of a maintenance program that was intended to check compliance of field grounding devices with ASTM F, field personnel.

Author: Zolobar Vohn
Country: Syria
Language: English (Spanish)
Genre: Politics
Published (Last): 22 May 2017
Pages: 399
PDF File Size: 6.58 Mb
ePub File Size: 8.32 Mb
ISBN: 743-5-30095-948-1
Downloads: 61228
Price: Free* [*Free Regsitration Required]
Uploader: Yokora

They use either an externally threaded ferrule or a ferrule that is drilled and internally astm f855. If the ground is improperly rated and fails before the system protection opens, astm f855 fault current will take any other available path, which includes personnel in contact with the faulted conductor.

However, it appears that F85 removed the acceptance of a compatible shrink installed over cable and ferrule as a means of cable restraint at least since the edition. Electrical Connection The electrical connection on the grounding clamp is known as the terminal. astm f855

Astm f855, 21 February Train the Trainer There are several methods of arriving at the total asymmetry of the fault current. Assemblies that have been subjected to these shall not be re-used. Clamps for Temporary Astm f855 Grounds. All cables must have strain relief. Grade 1 to Grade 7 Clamps Clamp grades 1 through 7 establish minimum requirements for physical strength and electrical characteristics in astm f855 rating, ultimate rating and continuous current, strength yield and ultimate strength.

In engineering terms this is known as DC offset. Subscribe to adtm blog post Unsubscribe. Lessons from Puerto Rico.

astm f855 Shrouded-type ferrules are designed to be used with ASTM-type grounding cable. The threaded ferrule is inserted through the drilled terminal. Assembly ratings assume the grade of lowest graded component see It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

Ferrules are rated Grade 1 to Grade 7 in withstand, ultimate and astm f855 current just as clamp grades 1 to 7, making electrical ratings easy to astm f855. If the cable is not compliant with the ASTM standard, the insulation may be too thick to fit under the ferrule shroud.

Resistance in the protective ground increases current across the worker in a fault. This standard does astm f855 purport to address all of the safety concerns, if any, associated with its use.

It is the responsibility of the user of f855 standard to establish appropriate safety, health, and astm f855 practices and determine the applicability of regulatory limitations prior to use.

After 25 years as a transmission-distribution astj and foreman, Jim Vaughn, CUSP, has devoted the last 20 years to safety and training. These specifications for a system of astm f855 grounding utilizing copper cables are covered in four parts, as follows: The ferrules shall be tested for electrical short-circuit capacity and continuous current rating.

This standard does ast, purport to address all of the safety concerns, if any, associated with its use. Continuous astm f855 ratings for ASTM-rated grounding-type cable is as follows: This maximum available fault astm f855 must be calculated to accurately select the required grounding components. Link to Active This link will always route to the current Active version of the standard.

The principal difference in each type is the temperature rating of the insulation and stranding of the conductor. The values in parentheses are the inch-pound units. astm f855

Each of the four parts is an entity of itself, but is listed as a part of the system for completeness and clarification. The narrow part of the sleeve is the f585 connector astm f855 is crimped onto the conductor strands.

Ferrule Types Ferrules are categorized according to ferrule-to-clamp astm f855 method and by either shrouded or nonshrouded. TPG testing is done on complete assemblies.

Popular Publishers

The ultimate rating is the current ratings the clamp can sustain in kA at 6, 15, atsm and 60 cycles. With the exception of Grade 7 in astm f855 ultimate category, all grades of clamps exceed the matching grade ground cable fault current ratings for the 6-,and cycle durations under the derated scenarios. Clamps for temporary protective grounds. The above current values are based on electromechanical test values. Cables for temporary protective grounds. Astm f855 29 CFR Most of the cables in the astm f855 are constructed to ASTM standards and satm performed well in utility use.

That is where preambles to the standards, interpretations, CPLs and consensus standards are needed. Calculating Fault Current Calculation of fault current is best accomplished through the services of an engineer experienced in utility systems. Pressure-type terminal connections use a astm f855 eye bolt inserted through a hole in the clamp. That is accomplished using a broad array of tools and rules for the employer and workforce.

Class B clamps have serrations or crosshatch patterns on astm f855 contact surface intended to abrade or bite through corrosion products on the surface of the astm f855.

Train the Trainer 101: ASTM F855 Grounding Equipment Specs Made Simple

Such calculation also assumes that the resistance between the station and the point of a fault will further limit the amount of power delivered into the fault. This abstract is a brief summary of the referenced standard. Subscribe to this blog post Please fill in your email address to subscribe to updates from this post.

To meet ASTM standards, temporary personal protective grounds must use multistranded flexible cable conductor installed in a rated clamp using protective cable ferrules. The concerns when considering non-ASTM-listed types of cable are astm f855 performance, proper stranding, astm f855 of the strand lay and alloying of the copper strand materials in the astm f855, all of which affect performance in a astm f855.